[OnyxCeph³™ Wiki]

DokuWiki - World Wide Web

User Tools

Site Tools


en:dtat2107

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
en:dtat2107 [2021/08/12 08:02] – [Import Interfaces] onyxadminen:dtat2107 [2021/10/25 09:15] (current) – [Import Interfaces] onyxadmin
Line 1: Line 1:
-<wrap right notice> 08/2021 </wrap> +<wrap right notice> 09/2021 </wrap> 
-======OnyxCeph³™ News======+======OnyxCeph³™ Release News======
 [[http://www.onyxceph.com/index.php?option=com_content&view=article&id=75&Itemid=68&lang=de|{{:start.png?200|}}]] [[http://www.onyxceph.com/index.php?option=com_content&view=article&id=75&Itemid=68&lang=de|{{:start.png?200|}}]]
 ---- ----
Line 8: Line 8:
  
 =====Import Interfaces===== =====Import Interfaces=====
-[[iteroimport|{{:dot1.png|1}}]] [[meditimport|{{:dot2.png|2}}]] Due to the increasing use of intraoral scanners, there is an increased interest in direct and easy to configure interfaces for scan import. To meet these requirements, several new interface options (for iTero, medit, CS3X00 and Trios, among others) have been implemented in recent months. For the portals [[iteroimport|MyiTero]] and [[meditimport|MeditLink]] these interfaces can already be used in the current [[release_notes|Softwarerelease]] 3.2.157.+[[iteroimport|{{:dot1.png|1}}]] [[meditimport|{{:dot2.png|2}}]] [[csdiimport|{{:dot3.png|3}}]] Due to the increasing use of intraoral scanners, there is an increased interest in direct and easy to configure interfaces for scan import. To meet these requirements, several new interface options (for iTero, medit, CS3X00 and Trios, among others) have been implemented in recent months. For the portals [[iteroimport|MyiTero]] and [[meditimport|MeditLink]] these interfaces can already be used in the current [[release_notes|Softwarerelease]] 3.2.157.
 \\  \\ 
  
 =====Module Retainer=====  =====Module Retainer===== 
-Starting with the upcoming release, there will be a direct interface for the retainer bending machine [[https://www.yoat1.com/|YOAT Bender 1]] in the [[retainer_3d|Retainer 3D module]] and a corresponding extension to the virtual round wire design. \\+[[6299|{{:dot1.png|1}}]] Starting with the upcoming release, there will be a direct interface for the retainer bending machine [[https://www.yoat1.com/|YOAT Bender 1]] in the [[retainer_3d|Retainer 3D module]] and a corresponding extension to the virtual round wire design. \\
  
 {{:fig_1.png?600&direct}}\\ {{:fig_1.png?600&direct}}\\
Line 20: Line 20:
 Also available in the upcoming release will be an option to send cephalometric side images in the [[digitize_2d|Evaluation module]] to the [[https://cellmatiq.com/|CellmatiQ]] service portal for AI-based retrieval and adoption of cephalometric fiducial locations in the image.\\ Also available in the upcoming release will be an option to send cephalometric side images in the [[digitize_2d|Evaluation module]] to the [[https://cellmatiq.com/|CellmatiQ]] service portal for AI-based retrieval and adoption of cephalometric fiducial locations in the image.\\
 \\  \\ 
 +{{:digitizecellmq.png?600&direct}}\\
 +\\
  
 =====Module Segmentation===== =====Module Segmentation=====
Line 41: Line 43:
  
 =====Module FA_Bonding=====  =====Module FA_Bonding===== 
-Since the user must always consider the desired target alignment of the relevant crown in the dental arch when placing brackets relative to the actual situation, additional numerical and visual control options have been implemented in the [[fa_bonding|module FA_Bonding]] to make it easier to find and evaluate the optimal position.\\+[[fclft_fab|{{:dot1.png|1}}]] Since the user must always consider the desired target alignment of the relevant crown in the dental arch when placing brackets relative to the actual situation, additional numerical and visual control options have been implemented in the [[fa_bonding|module FA_Bonding]] to make it easier to find and evaluate the optimal position.\\
  
 {{:fig_4.png?600&direct}}\\ {{:fig_4.png?600&direct}}\\
Line 47: Line 49:
    
 =====Module Bonding Trays 3D=====  =====Module Bonding Trays 3D===== 
-[[fclft_btray|{{:dot1.png|1}}]] In collaboration with 3M, an IBT design option specifically tailored to APC™ Flash-Free™ Brackets was developed, integrated and tested in the [[bonding_trays_3d|Bonding Trays Module]]. Additionally, the initialization of the inner trim line has been improved and endpoints for the last bracket crown have been added to ensure homogeneous stiffness of the IBT. \\+[[fclft_btray|{{:dot1.png|1}}]] In collaboration with 3Ma new Digital-IBT design option specifically applicable to APC™ Flash-Free™ Brackets was developed, integrated and tested in the [[bonding_trays_3d|Bonding Trays Module]]. Additionally, the initialization of the inner trim line has been improved and endpoints for the last bracket crown have been added to ensure homogeneous stiffness of the IBT. \\
  
-{{:fig_5.png?600&direct}}\\+{{:fig_51.png?600&direct}}\\
 \\ \\
    
 =====Visualization=====  =====Visualization===== 
-Finally, new OpenGL shaders have been developed to, among other things, render textured tooth and soft tissue surfaces more realistically and optimize view options such as highlight, brightness, and blur based on the situation.+Finally, new OpenGL shaders have been developed to, among other things, render textured tooth and soft tissue surfaces more realistically and optimize view options such as highlight, brightness, and blur based on the situation (see screenshots for modules Retainer 3D, FA_Bonding and Bonding Trays above on this page).
 ---- ----
  
en/dtat2107.1628748122.txt.gz · Last modified: 2021/08/12 08:02 by onyxadmin