en:fa_concept
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
en:fa_concept [2022/05/02 17:43] – onyxadmin | en:fa_concept [2022/05/03 10:05] (current) – onyxadmin | ||
---|---|---|---|
Line 3: | Line 3: | ||
---- | ---- | ||
- | =====Idea===== | + | =====Concept===== |
The basic idea behind so-called bracket placement rules is that the position of the bracket relative to the crown in malocclusion is reproducibly specified by the vertical¹ incisal edge distance along the facial clinical crown axis FACC. This value can be fix or calculated variably from parameters such as crown heights, distance to other reference crowns or other measures. Among other things, distance rulers (e.g., the " | The basic idea behind so-called bracket placement rules is that the position of the bracket relative to the crown in malocclusion is reproducibly specified by the vertical¹ incisal edge distance along the facial clinical crown axis FACC. This value can be fix or calculated variably from parameters such as crown heights, distance to other reference crowns or other measures. Among other things, distance rulers (e.g., the " | ||
In the [[fa_bonding|FA_Bonding]] module, various such placement rules can be selected and applied for the initial placement of the selected virtual bracket. | In the [[fa_bonding|FA_Bonding]] module, various such placement rules can be selected and applied for the initial placement of the selected virtual bracket. | ||
Line 14: | Line 14: | ||
* Alexander | * Alexander | ||
- | \\ | + | In addition, the user can define multiple sets for his own fix bonding distances and save or apply them under its own name. |
^ Variable Placement Rules ^^^ | ^ Variable Placement Rules ^^^ | ||
| {{: | | {{: | ||
Line 24: | Line 24: | ||
---------\\ | ---------\\ | ||
- | ¹ senkrecht zum Bracketslot | + | ¹ perpendicular to the bracket slot\\ |
+ | \\ | ||
- | =====Problem===== | + | =====Challenge===== |
When applying this widely used methodology, | When applying this widely used methodology, | ||
In der Praxis wird diese Winkel vor dem Hintergrund der unbewussten Validierung durch den erfahrenen Behandler meist so eingestellt, | In der Praxis wird diese Winkel vor dem Hintergrund der unbewussten Validierung durch den erfahrenen Behandler meist so eingestellt, | ||
Line 42: | Line 43: | ||
\\ | \\ | ||
- | ^ | + | ^ |
| [[fa_bl|{{: | | [[fa_bl|{{: | ||
- | | 5,04 mm | | + | | |
\\ | \\ | ||
en/fa_concept.1651506215.txt.gz · Last modified: 2022/05/02 17:43 by onyxadmin