Line 1: Line 1:
-~~NOTOC~~ +====== Interface Configuration Digital Xray: Sidexis ======
-===== Interface Configuration Digital Xray: Sidexis =====+
 ---- ----
 +[[settings_digitalxray|{{:sidexis.png|}}]]\\
 +\\
 +====Sirona Sidexis - Support Activated====
 +Activation of the [Digital X-ray] icon button in the [[:add_image_2D|Add image 2D]] module.
  
-[[settings_digitalxray|{{:sidexis.png|}}]]+====Sidexis Program Path===== 
 +Local path to the executable file ..\Sidexis(4).exe \\ 
 +The program path only needs to be configured if Sidexis is to be called directly from OnyxCeph³(tm) via [Go to].\\ 
 + 
 +====Mailslot-Import==== 
 +Path of the OnyxCeph mailbox file that was entered in the Sidexis settings under Communication partners.\\ 
 +++++Settings Communication partners in Sidexis| 
 +{{:sidexis4_kommunikationspartner.png?&direct}} 
 +++++  
 +Checkbox [Receives copies of new images automaticallyensures that newly captured images are automatically transferred to the mailslot and thus immediately displayed in the [[:add_image_2D|Add image 2D]] module in OnyxCeph³(tm). Alternatively, images can be added manually to the mailslot in Sidexis.\\ 
 +{{:sidexis4_mailslotexport.png?&direct600}}\\  
 +====Mailslot-Export==== 
 +Path of the SLIDA mailbox file that was entered in the Sidexis settings under Communication partner.\\ 
 +++++Settings multi-user in Sidexis| 
 +{{:sidexis4_mehrplatz.png?&direct}} 
 +++++  
 +The entry is only required if the Sidexis program is to be called from OnyxCeph³(tm).\\ 
 +Optionally, you can specify whether patients who do not yet exist should be selected or whether deviating patient data should be compared.\\ 
 +\\
  
-^ Parameter                           ^ Setting                                                            ^ +====Database-Import (obsolete)==== 
-| [Unterstützung aktiv]               | Aktivierung der Importtaste im Modul Bild hinzufügen 2D                | +Path of the Sidexis image database PDATA. The entry is only required if the image database is to be read out directlyThis option may require the installation of additional database drivers and is no longer supported from Sidexis 4.4 onwards for data protection reasons.\ 
-| Programmpfad [...]                  | Lokaler Pfad zur ausführbaren Datei ..\Sidexis(4).exe                  | +Optionally, you can specify whether the database images should be mirrored vertically and/or inverted.\\
-| [Station]                           | Rechnername zur Bilddatenbank PDATA                                    | +
-| Pfad der Bilddatenbank [...]        | UNC-Pfad ..\PDATA                                                      |   +
-Sidexis - Briefkastendatei [...]    | UNC-Pfad ..\slida.sdx (wenn konfiguriert)                              |   +
-| OnyxCeph - Briefkastendatei [...]   | UNC-Pfad ..\onyx.sdx (wenn konfiguriert)                                 +
-| [Neue Patienten]                    | Übergabe neuer Patientendaten bei Aufruf                               | +
-| [Änderungen]                        | Abgleich vorhandener Patientendaten bei Aufruf                         | +
-| [Test]                              | Test Datenbankzugriff                                                  | +
-| [Bei Übergabe vertikal spiegeln]    | Bild bei Übergabe vertikal spiegeln                                    | +
-| [Bei Übergabe invertieren]          | Bild bei Übergabe invertieren                                          |+
  
 +//Note//: The raw images stored in the image database do not contain any image processing steps or conversions applied in the Sidexis application (unlike with mailslot transfer).
 \\ \\
-==== Einrichten der Schnittstelle ==== 
-Bilder aus der Sidexis-Datenbank können entweder (A) von OnyxCeph³™ aus direkt im Original übernommen oder (B) optional nach manueller Bildbearbeitung in der Sidexis-Software über Briefkastendatei ("Mailslot") von Sidexis aus aktiv an OnyxCeph³™ übergeben werden.\\ 
  
-Für die Kopplung von OnyxCeph³™ und Sidexis muss im Konfigurationsdialog mit Hilfe der Durchsuchen-Taste [...] die ausführbare Datei Sidexis.exe bzw. Sidexis4.exe im Sidexis-Programmpfad gesucht und übernommen werden. Mit Übernahme der Programmdatei werden die Einträge zur Datenbank und zu den Mailslot-Dateien automatisch gesucht und in den betreffenden Feldern angezeigt. Die Mailslot-Datei für OnyxCeph³™ muss zuvor in der Sidexis-Software konfiguriert worden sein.\\ 
  
  
-^Hinweis^ 
-|Findet keine Bildbearbeitung in der Sidexis-Software statt, sollte Methode (A) genutzt werden. Voraussetzung für deren Funktion ist die korrekte Installation der ODBC-Treibersoftware. Das kann über die Windows Systemsteuerung kontrolliert werden. Über das Element Verwaltung kann der Dialog ODBC-Datenquellen gestartet werden. Bei korrekter Installation sollte dort im Tab Benutzer-DSN und/oder System-DSN ein Treiber eingetragen sein. Andernfalls den Anwender darauf hinweisen, die Installation nachzuholen.| 
en/sidexis.1611927245.txt.gz · Last modified: 2021/01/29 14:34 by onyxadmin